The AP200 180kVA Perkins diesel generator set is a heavy-duty industrial standby power unit independently developed by Aike Power, matched with original UK Perkins 1106A-70TAG3 turbocharged intercooled engine and self-excited brushless AP200 alternator with pure sine wave output.
Equipped with multi-grade Deepsea intelligent control system, it supports auto start, automatic mains failure transfer, multi-unit parallel operation and remote communication monitoring. Two structural options (open frame / soundproof silent canopy) are available to cover construction mining, hospital critical backup, commercial complex, off-grid plateau and factory emergency power supply scenarios.
Every AP200 genset undergoes full-load aging testing before delivery, fully compliant with ISO 8528, IEC and CE international standards, featuring stable continuous operation, low fuel consumption and outstanding harsh environment adaptability.
Matched with self-developed AIKE AP200 brushless alternator with H-class insulation and IP23 dust & splash protection grade. Optimized star winding design limits total harmonic distortion below 2%, steady-state voltage regulation within ±1%.
The smooth pure sine wave current brings no waveform distortion, capable of stably driving all types of nonlinear loads including medical precision instruments, PLC control systems, frequency converters and server data center equipment. Tested alternator efficiency reaches up to 93.1% to reduce power loss during long-term operation.
Powered by authentic UK Perkins 6-cylinder inline turbo intercooled engine, bore × stroke 105mm × 135mm, total displacement 7.01L. Mechanical governor system realizes precise fuel injection control, standby engine gross power reaches 177kW.
With mature 16:1 compression ratio design, the engine owns strong cold start performance under -40℃ low temperature. Complete lubrication & cooling system (16.5L oil capacity, 21L coolant capacity) extends overhaul cycle, reducing long-term maintenance frequency and cost for global clients.
Fuel consumption data under standard working condition:
100% PRP: 41.2 L/h | 75% PRP: 30.9 L/h | 50% PRP: 20.6 L/h
The AP200 genset runs reliably under -40℃ ~ 55℃ wide temperature range with reinforced cold start auxiliary system, perfectly adapting to frigid polar regions, tropical high-humidity coastal areas and sandstorm mining zones.
Standard model supports stable operation under altitude ≤1500m; customized plateau modification version is available for 5000m high altitude areas with low power derating. Optional supporting accessories: water jacket preheater, water-oil separator for extreme low-temperature working sites.
Equipped with high-performance rubber anti-vibration mounts and rigid integrated steel base frame, the compact integrated structure effectively cuts mechanical vibration and running noise. Matched with industrial silencer and ripple flexible exhaust pipeline to suppress exhaust noise.
The optimized Perkins combustion system controls fuel consumption at a low level under all load ratios, greatly lowering long-term operation expenditure for industrial projects, while exhaust emission indicators meet international industrial environmental standards.
Whole unit adopts standardized modular layout with highly universal spare parts, simplifying daily maintenance and global accessory procurement. The original Perkins engine enjoys global official after-sales spare parts network, no difficulty in component replacement worldwide.
The matching dry air filter, fuel filter and oil filter adopt general international specifications, clients can purchase replacement parts locally without long lead time, effectively reducing project downtime loss.
Built-in main circuit breaker to block overload & short-circuit risks instantly. The Deepsea control panel integrates full automatic shutdown protection functions: low lubrication oil pressure, high coolant temperature, over-speed, under/over voltage, frequency deviation alarm & protection.
Complete safety guard covers fan belts, dual 12V starting batteries and anti-backfire exhaust structure, effectively avoiding unexpected equipment damage and operation safety hazards for long-time unattended running.
| Item | Specification |
|---|---|
| Model | AP200 |
| Prime Power | 144kW / 180kVA |
| Standby Power | 160kW / 200kVA |
| Rated Frequency | 50Hz |
| Rated Rotate Speed | 1500 RPM |
| Rated Output Voltage | 400/230V, 3 Phase 4 Wire |
| Power Factor | 0.8 Lagging |
| Standard Applicable Altitude | ≤1500m |
| Ambient Operating Temperature | -40℃ ~ 55℃ |
| Open Frame Dimension (L×W×H) | 2550 × 930 × 1670 mm |
| Silent Canopy Dimension (L×W×H) | 3590 × 1150 × 2050 mm |
| Engine Parameter | Data |
|---|---|
| Manufacturer | PERKINS (UK Original) |
| Model | 1106A-70TAG3 |
| Cylinder Layout | Inline 6 Cylinders |
| Displacement | 7.01 L |
| Bore × Stroke | 105mm × 135mm |
| Compression Ratio | 16:1 |
| Aspiration | Turbocharged & Intercooled |
| Governor Type | Mechanical Governor |
| Cooling Mode | Water Cooling |
| Coolant Capacity | 21 L |
| Lubrication Oil Capacity | 16.5 L |
| Electrical System | 12 VDC |
| Standby Gross Engine Power | 177kW |
| Alternator Item | Parameter |
|---|---|
| Brand & Model | AIKE POWER AP200 |
| Phase Quantity | 3 Phases |
| Power Factor | 0.8 |
| Bearing Type | Single Bearing |
| Pole Number | 4 Poles |
| Insulation Class | H Class |
| Protection Degree | IP23 |
| Excitation Mode | Brushless AVR Automatic Voltage Regulator |
| Connection Type | Star Connection |
| No-Load Total Harmonic Distortion | < 2% |
| Rated Standby Power | 200kVA |
| Alternator Efficiency | 93.1% |
Safety fan guard, belt-driven cooling fan, radiator assembly, dry air/fuel/oil filter set, main circuit breaker, dual 12V starting batteries, ripple flexible exhaust pipe, industrial muffler, anti-vibration shock mounts, rigid integrated steel base frame.
All AP200 Perkins generator sets pass mainstream international industry certifications, fully meeting global tender project access requirements:
As an official authorized Perkins power unit manufacturer, Aike Power owns complete independent production workshop and dedicated full-load test laboratory. Every finished AP200 genset undergoes full-load aging test, pure sine waveform detection, high-low temperature simulation inspection before factory delivery.
Factory customization support: Global multi-standard voltage customization (380/220V, 415/240V, 440/254V), OEM brand logo printing, bulk container integrated delivery.
Unified standard warranty policy (whichever expires first):
Global after-sales service network: Local authorized distributors provide global spare parts supply, remote controller online debugging guidance, generator operation & maintenance technical training for project teams.
A: Prime power 144kW is continuous long-duration stable running power; standby power 160kW only applies to short-time emergency peak load, cannot operate continuously under full standby power rating.
A: Standard unit adapts altitude below 1500m; we provide customized plateau modification version with adjusted fuel injection parameters to reduce power deration for 5000m extreme high-altitude working environments.
A: Alternator no-load THD < 2%, pure sine wave stable output with voltage fluctuation ≤±1%, fully compatible with medical equipment, PLC, frequency converters and all kinds of nonlinear precision loads.
A: 100% load: 41.2 L/h, 75% load: 30.9 L/h, 50% load: 20.6 L/h, data tested under standard 25℃ ambient condition.
A: 15 months after shipment / 1 year after on-site installation / 1000 accumulated running hours, take the earliest expired term as standard warranty coverage.
A: Yes, silent soundproof canopy, ATS dual power transfer switch, multi-unit parallel control panel and mobile trailer chassis are all available customized optional accessories.